Problem 2 (50 points): Two three-phase generators supply a three-phase load through separate three- phase lines. The load absorbs 30 kW at 0.8 power factor lagging. The line impedance is (1.4+1.6) 2 per phase between generator Gl and the load, and (0.8 +j) 2 per phase between generator G2 and the load. If generator Gl supplies 15 kW at 0.8 power factor lagging, with a terminal voltage of 460 V line-to-line, determine 1. The voltage at the load terminals. 2. The voltage at the terminals of generator G2. 3. The real and reactive power supplied by generator G2. Assume balanced operations